How do you delete test signals from the TG700?

質問:

How do you delete test signals from the TG700?

回答:

Signals are deleted from the TG700 using the TG7COMM program. Open the TG7COMM; provide the IP address of the TG700. Open the module you want to delete signals from. Open the SIGNAL or Picture folder, as appropriate, then the folder for the format you want to remove signals from. At this point, you can open the individual button level folders, highlight the signal to be deleted, and then hit the DELETE key. There is no way to delete whole blocks of signals. They must be done individually.

Note: Only the AVG7, DVG7, HDVG7, and AWVG7 modules allow signals to be added and deleted.